In the case of an enquiry for PBT flame retardant materials, if it merely states 'halogen-free, V-0, with glass fibre', it is impossible to provide a meaningful quotation.

As technical specialists, we are well aware that this is not a case of suppliers withholding information, but rather a lack of sufficient details. Without clearly defined parameters, any quoted price is merely a guess. A price arrived at by guesswork is bound to fall apart once the prototyping stage begins, leading to endless wrangling between buyer and supplier.

The following six questions are the 'technical pitfalls'that cannot be avoided when evaluating any PBT flame-retardant project. Get any one of them wrong, and all subsequent efforts will essentially be for naught.

1124-A Guide to Avoiding Pitfalls When Enquiring About PBT Flame Retardants

Question 1: What colour is the component? — The 'veto power'that determines the material system

Why ask this: Colour is a hard physical constraint; it is not something where costs can be reduced through negotiation. Red phosphorus is naturally dark red; if you add it to a light-coloured component, the result will be pink. If a customer says, 'Add some whitened red phosphorus', that is a different product altogether, not standard red phosphorus.

Technical Limitations:

  • White, light colours, and coloured parts: Red phosphorus is immediately ruled out; only organic phosphorus systems can be used, such as halogen-free white compounds (e.g. YS-M330G).

  • Dark colours and black: Red phosphorus systems can be used, such as FRP-750A (red) or FRP-750AH (black); a 10 per cent addition is sufficient to achieve V-0/2.0 mm.

  • Avoiding pitfalls: When a customer mentions 'dark colours', you must ask for the specific colour family. If the colour is army green, dark blue or dark grey, adding red phosphorus will still cause colour deviation. The only colours that are truly suitable are pure black and very dark brown. The method for determining this is simple: take a small sample of the material, cut a small test piece and compare it against a sheet of white paper.


Question 2: What are the minimum and maximum wall thicknesses of the component? — The 'Sword of Damocles' behind the UL 94 rating

Why we ask: UL 94 flame retardancy ratings are always tied to thickness. A V-0 report for 2.0 mm does not cover 1.6 mm, let alone 0.8 mm.

Technical Limitations:

  • It is essential to ascertain both the minimum and maximum wall thicknesses. Asking only for the minimum thickness is insufficient; if the thickness ratio exceeds 2, issues such as weld lines, shrinkage cavities and carbon layer collapse will arise. In such cases, the rating must be determined based on the thinnest point, whilst the manufacturing process must be defined according to the thickest point.

  • Practical experience: If a customer states, 'It's just a 2.0 mm board', you must always follow up with: 'Does it have ribs, bosses or snap-fits?'For parts with ribs, the actual thinnest point is often located on the rib itself.

UL94 ratings are always tied to thickness. A V-0 report for 2.0 mm cannot cover 1.6 mm, nor can it cover 0.8 mm.

1124-UL 94 rating and thickness

Question 3: Glass fibre content — Physical backlash under the 'wick effect'

Why this question: In flame-retardant formulations, 0 per cent glass fibre and 30 per cent glass fibre are worlds apart.

Technical limitations:

  • PBT without glass fibre is inherently V-2 rated; it self-extinguishes whilst dripping, so adding flame retardants is relatively straightforward.

  • Once 30 per cent glass fibre is added, dripping is suppressed and heat remains in the material; the LOI plummets from 24.5 to 19.1, and the rating drops from V-2 to HB. At this stage, the charring capability must be re-established, and the dosage, system composition and dispersion must all be recalculated.

  • Further considerations: Is the glass fibre long or short? When is it introduced? Whether fed in at the rear or at the front, a difference in fibre length of one to one results in completely different flame-retardant and mechanical properties.


Question 4: Is CTI required, and if so, what value? — The hidden killer of electrical performance

Reason for asking: When a customer says 'we need a high CTI', this is not a actionable technical specification. Products rated at 600V and 250V are entirely different.

Technical limitations:

  • It is essential to ask for specific values, as well as the test conditions: is this the initial state, or following damp-heat ageing? There can be a one-grade difference between the two.

  • Technical clarification: A high CTI is not exclusive to halogen-free organophosphorus compounds. CTI values of 600V can also be achieved with red phosphorus masterbatch systems. The real difference lies in long-term leaching — the acidic leachates from red phosphorus can affect metal inserts and long-term electrical performance, which is where the quality of the coating must provide a safety net.

  • If a customer requires both a dark colour and 600 V, do not immediately rule out red phosphorus; first clarify the material of their metal inserts and their ageing requirements.


Question 5: What proportion of recycled material is intended to be blended in? — The trade-off between degradation and flame retardancy efficiency

Why ask: This point is often overlooked, yet it directly determines which formulation grade to recommend.

Technical constraints:

  • For dark-coloured parts with 10% red phosphorus, the formulation remains adjustable even with 25–30% recycled material. With organophosphorus systems, if the content is around 15%, formulation flexibility is compromised; as the recycled material proportion increases, both melt strength and flame retardancy will fluctuate.

  • Key follow-up question: Is the recycled material in-house sprues or externally sourced regrind? The thermal history of sprues is well-documented, whereas the IV and terminal carboxyl groups of externally sourced material are unknown. Material with high terminal carboxyl groups will 'consume' the phosphorus-based flame retardant, causing the IV to drop steadily and rendering the flame retardancy ineffective.


Question 6: The client's prohibited substances list – an OEM's 'minefield'

Why ask: This point is the easiest to overlook, yet the consequences can be the most severe.

Technical considerations:

  • Some electronics brands explicitly exclude red phosphorus from their material specifications (citing risks associated with phosphine and incineration); others exclude all halogens; whilst some impose additional requirements for food contact, toys and medical applications.

  • Ask specifically: 'Do your customers' specifications explicitly prohibit red phosphorus, ban halogens, or require a particular environmental label?' If the other party replies, 'I don't think so', make sure they check. One check can save you the cost of a sample run.


The Cost of an Incorrect Answer

1124-The price of getting it wrong


Summary: The 'Three-Dimensional Quick Assessment Method'for Engineers

Although these six questions may appear disparate, they are all addressing the same fundamental issue: what is permitted and what is not permitted for this part.

Red phosphorus is not permitted in the colour formulation. Lower-grade wall thicknesses are not permitted. Simply increasing the glass fibre content is not permitted. Arbitrary changes to the electrical performance system are not permitted. High-filler recycled materials are not permitted. Certain chemicals on the prohibited list are not permitted.

Once these six boundaries are defined, there are usually only one or two viable solutions remaining. Conversely, if a quotation is provided without asking these six questions, what is offered is a 'generic recommendation', not 'your specific solution'.


A more time-efficient approach

If the client finds six questions too many, just three will suffice: colour, minimum wall thickness and glass fibre content.

These three can determine the direction of 80 per cent of the solutions; the remainder can be addressed during the prototyping stage. However, CTI and the list of prohibited substances must be finalised before prototyping begins; one cannot wait until the test reports are available.


Our approach

Once we have these six answers, we will provide an initial proposal: the system, the recommended reinforcement range, the thicknesses requiring testing, and a clear statement of ‘what is not feasible’.

We will be straightforward about what is not feasible. For example, if a 0.8 mm part requires both V-0 flammability rating and 30 per cent glass fibre content, we will inform you of the risks associated with this combination, rather than accepting the order first and addressing it later.

For dark-coloured parts, start with FRP-750Aor FRP-750AH; for light-coloured parts, start with YS-M330G. The filler content, grade and packaging for all three grades are listed on the product pages; if you are unsure, please send us the part drawings.

1124-Quick Reference Guide for SelectingPBT Flame-Retardant Products


Five supplementary questions regarding PBT flame retardancy

Q1: Is it acceptable if a customer simply says 'V-0' without specifying the thickness?

No. V-0 must be specified in conjunction with the thickness, and the quotation must clearly state which thickness it covers.


Q2: A customer requires 'halogen-free' – does red phosphorus count as halogen-free?

Yes. Red phosphorus is elemental phosphorus, contains no halogens, and complies with RoHS/REACH. However, ‘halogen-free’ and ‘permitted on the client’s list’ are two separate matters.


Q3: The client wants a white part but also wants it to be cheap. How should we respond?

Be honest: white parts can only be achieved using organophosphorus compounds, which require a dosage approximately five percentage points higher than red phosphorus. This translates to a cost increase of around 15 per cent, not double the price. Offer a compromise solution, such as using red phosphorus with a covering agent for light grey parts, but ensure a sample is produced first to confirm the colour.


Q4: The customer's part has already been tooled; what if the wall thickness cannot be changed?

Submit it for testing at the existing wall thickness to obtain the actual grade, then discuss whether this is acceptable. If the structure cannot be altered, the expectations will have to be adjusted; this point must be raised early on.


Q5: Will the quoted price inevitably change after prototyping?

If all six questions have been clarified, changes will typically be limited to minor adjustments in content levels. If they have not been clarified, the price may double.


Yinsu flame retardant is a factory, focuses on manufacturing non halogen, low smoke and non-toxic flame retardants for various of applications. 
We also supply tailor flame retardant solutions.
 
Office: No. 26, Kaitai Road, Huangpu District, Guangzhou City, Guangdong Province, China

Quick Links

Contact Us
Copyright 2022 Guangzhou Yinsu Flame Retardant New Material Co., Ltd. Technology by Leadong. Sitemap.